The Model TL7 is a panel-mounted flashing alarm light and audible alarm driver. The TL7 helps protect the Murphy Swichgage® contacts from the very high inrush current of the lamp. It is available in 12- or 24-VDC for negative ground systems. The SAH Mini-siren provides an audible alarm when fault conditions are detected by a Swichgage instrument. It can be panel mounted and operates on 6–28 VDC.
The TL7 Flasher/Light is used as a warning device on various types of industrial and mobile equipment. The Mini-siren will give an audible warning when the TL7 operates, or it can be wired directly to the Swichgage contacts for audible only alarm.
Specifications
TL7
- Power Requirements:
- Voltage: 12 or 24 VDC, negative ground (specify voltage)
- Current:
- - Sensor switch < 60 mA
- - 12 VDC, 360 mA with lamp on
- - 24 VDC, 200 mA with lamp on
- - 12 or 24VDC, 5 mA standby, lamp off
- Outputs (see replacement lamps):
- Lamp output: 120 mA @ 14.4 VDC
- SAH terminal: 20 mA @ 28 VDC resistive
- Enclosure: Red polycarbonate lens with aluminum retaining nut
- Temperature Range: -40° to 165°F (-40° to 74°C)
- Terminal Connections: Four tin plated 1/32 x 1/4 in. (0.8 x 6 mm) male push-on type terminal
- Mounting Hole: 1-1/8 in. (29 mm) diameter
- Maximum Panel Thickness: 1/4 in. (6 mm)
SAH
- Type: PIEZO electric transducer
- Operating Voltage: 6–8 VDC
- Output Level: at 28 VDC 1 meter, 90± 5 dB
- Current Drain: at 28 VDC, 20 mA MAX
- Mounting Hole: 1-1/8 in. (29 mm) diameter
- Maximum Panel Thickness: 1/8 in. (3 mm)
For more information about this product, you can download the related literature here: