Current Manual(s)
- Installation Manual (00-02-0977)
- Operations Manual (00-02-0939; Config Version 2.9.20025)
- Application Version 02.09.10054; Config Version 2.9.20025
- Quick Help Guides
-
Software Release Notifications with Past Manuals
- Application Version 02.09.10054; Config Version 2.9.20025
- Application Version 02.09.10051; Config Version 2.9.20024
- Application Version 02.09.10051; Config Version 2.9.20016
- Application Version 02.08.10161
- Application Version 02.08.10133.00
- Application Version 02.08.10128.00
- Application Version 02.08.10073.00
PowerVision for Controllers
PowerVision For Controllers is a simplified version of the PowerVision Configuration Studio® PC-based software program suite used to configure controllers and displays. This version lets you create customized configurations for controllers such as the MPC-20, MPC-10 and TEC-10 without needing to know how to write code. It is freely available to anyone that wants to configure a Murphy by Enovation Controls controller.
Downloads:
- TEC-10 Configuration version 20029
-
PowerVision for Controllers Downloads (Account Required)
- Downloads of PowerVision for Controllers are only available on this site to users with registered accounts. To register for a free account, click here. Having trouble accessing your account? Contact Account Support.
- PowerVision for Controllers Tutorial
- Solid Models
- CE Declaration of Conformity
No Demo Configurations or Examples available at this time.
- Programming Harness 40000626
- Connector kits, EMEA regions (ys6475)
-
Interface:
-
Display:
- Monochrome HR-TFT
- 2.7 in./ 68 mm, WQVGA (400 x 240 pixels)
- Languages: English, Spanish, German, French, Italian
- (3) LEDs: green (mode), yellow (warning) and red (shutdown)
-
Operator controls:
- (11) Raised silicone keypads, tactile feedback
- (1) Rotary switch, power on/off
- (1) Push-switch (red), engine stop
- (1) ATC Fuse, 25A
-
Display:
-
Power Supply:
- Operating Voltage: 8-32 VDC, reverse battery polarity and load dump protected
- Cranking Power Holdup: 0 VDC up to 50 mS(also good for brownout/blackout instances)
- Current consumption: Power on in stopped state; 117 mA at 12 VDC. Power on in standby mode; 52 mA at 12 VDC.
-
Inputs (9):
- (5) Digital, configurable (active on High, Low, Open)
- (3) Analog, configurable (4-20 mA, 0-5V, resistive or digital ground)
- (1) Frequency, supporting: Magnetic pickup (30 Hz - 10 kHz, 2.0 VAC-120 VAC) and Engine Alternator (30 Hz - 10 kHz, 4.5 VRMS - 90 VRMS)
-
Outputs (8):
- (2) Relay, switched +DC, 10A
- (1) Relay, Form C (dry / volt-free), 10A
- (2) Low-side FET (–DC), 1A
- (2) High-side FET (+DC), 1A
- (1) Dedicated Alternator Excitation, +DC, 1A
-
Communications:
- (1) CAN: J1939
- (1) RS485: Modbus RTU
-
Mating Connectors:
- 21 Position, Deutsch HDP26-24-21SE
- 31 Position, Deutsch HDP26-24-31SE
- Physical/Environmental:
- Enclosure material: Polycarbonate
- Dimensions (WxHxD): 9.59 x 7.34 x 5.20 in. (243.48 x 186.5 x 132.23mm)
- Weight: 4 lbs (1.8 kg)
- IP rating: IP67
- Operating Temperature: -40° to +85° C (-40° to 185° F)
- Storage Temperature: -40° to +85° C (-40° to 185° F)
- Vibration: 7.86 Grms (5-2000 Hz), 3-axis random
- Shock: ±50G, 3-axis