Modex Automation specialized in the design and manufacture of control equipment for the standby diesel generator, process control and packaging equipment industries. The company – originally based in Hayling Island, Hampshire, UK – became part of the Murphy group in 1997.
Some Modex products, including Autostart and Keystart controls, are still manufactured by Enovation Controls under the Murphy brand. Archive information is also available for special and discontinued products. For details about serial numbers and date codes on Modex-designed product, click here.
Discontinued Modex Automation Products
- A200-2(P)(C)
- Discontinued Modex Automation 2 channel annunciator, 96mm (w) x 48mm (h).
- A200-3(P)(C)
- Discontinued Modex Automation 3 channel annunciator, 96mm (w) x 48mm (h).
- A200-4(P)(C) / A201-4(P)(C)
- Discontinued Modex Automation engine/generator controllers, 96 x 96mm DIN. The range also included special variants A203-4, A210-4, A211-4, A213-4, A215-4 and A217-4. The nearest equivalents are the Autostart AS7xx controls.
- A301 (Alpha front label)
- Discontinued Modex Automation special variant of the Manustart controller. Superseded on Slingtons/Hallmark generators by the A302(OS) - see below.
- A302/A302OS (Alpha front label)
- Discontinued Modex Automation special variant of the Keystart 9600 range. Standard Keystarts have a rear facia switch bank for selection of power supply (12 or 24VDC) and fault input polarity (open/close to +ve/-ve during fault), but the A302(OS) is 1) factory preset for 12 or 24 VDC, 2) fault inputs are preset at closed to negative on fault. The nearest equivalent to the A302 was the Keystart 9600; nearest equivalent for the A302OS (AC sensing overspeed trip) was the Keystart 9602.
- A401 (Alpha front label)
- A special variant of the Autostart AS700 produced for Slingtons/Hallmark generators. Differences from the AS700 include 1) special front label, with Alpha branding and keyswitch MANUAL mode (replacing TEST), 2) a manual mode output on pin 5 (instead of a magnetic pickup input), 3) different adjustment ranges for some timers, 4) the unit will NOT automatically start the engine if a mains fail occurs when the keyswitch is set to manual mode.
- A500 series
- Discontinued range of Modex Automation alarm / annunciator module, 96 x 96mm DIN. Many hardware variants were produced, each defined by a specification number (e.g. A110, A103). There is no direct Murphy equivalent.
- A600-6/A600-4
- Discontinued Modex Automation engine/generator controller (A600-6) and AMF/ATS module (A600-4), specially produced for Dawson Keith Ltd. No direct equivalent.
- Alpha
- Alpha branded products produced by Modex Automation for Hallmark/Slingtons generators. See entries above for A301, A302 and A401.
- AS711
- Discontinued Modex Automation Autostart engine/generator controller. Originally superseded by model AS705.
- AS720
- Discontinued Modex Automation Autostart module, similar to AS710 plus mains voltage monitoring.
- BC700 / BC701
- A range of (ex-Modex Automation) 3 Amp constant current battery chargers, discontinued in mid-2004. BC700 models were for 12V systems, BC701 were for 24V systems.
- CVT100 series
- Discontinued Modex Automation range of general purpose DC signal current and voltage trip relays, housed in an 11 pin plug-in case
- CVT500 / CVT501 series
- Discontinued range of general purpose DC and AC signal current and voltage trip relays, housed in a DIN-rail/surface mount case.
- CVT502 / CVT506 / CVT508
- Discontinued Modex Automation under voltage monitoring relays for 12/24/48V battery and DC systems. No direct equivalent.
- CVT503
- Discontinued Modex Automation temperature control relay, for engine jacket heater control using a VDO temperature sender. No direct equivalent.
- CVT504
- Discontinued Modex Automation AC check-synch relay. No direct equivalent.
- DCM series
- Discontinued Modex Automation motor speed controller. No equivalent.
- DT1000(V)(H)
- Discontinued Modex Automation 12 channel temperature indicator, 3 digit LED display, 48 x 96mm.
- ECD, ELD, ERC series
- Discontinued range of residual current earth leakage detector relays and core balance transformers, originally manufactured by Brian Bennett Electrical Engineering Ltd. (BBEE) and Modex Automation.
- ET25
- Discontinued Modex Automation encapsulated timer (delay on energisation with blade connectors). No Murphy equivalent.
- HFT series
- Discontinued Modex Automation High Frequency Trip relay. Originally superseded by the OFR range (also now discontinued, with no direct equivalent).
- HT100
- Discontinued Modex Automation humidity trip relay (11 pin plug in).
- ID500
- Discontinued Modex Automation film scanner for packaging equipment. No direct equivalent.
- LFT series
- Discontinued Modex Automation Low Frequency Trip relay. Originally superseded by the UFR range (also now discontinued, with no direct equivalent).
- Manustart
- Discontinued Modex Automation engine controller, manual start. Superseded by (but not pin compatible with) the Keystart range.
- MFU series
- Discontinued Modex Automation Mains Failure relays (3 phase, no neutral). Originally superseded by PFR range (also now discontinued, with no direct equivalent).
- Microstart MS1A, MS1D
- Discontinued Modex Automation full AMF generator controller. Models included MS1A (for use with AC coiled contactors) and MS1D (for use with DC coiled contactors). Models with a 'C' suffix are fitted with a remote communications option.
- OST100/OST101
- Discontinued Modex Automation over speed/frequency trip relays with 11 pin plug in case, 12 or 24V DC auxiliary supply, 110/240VAC input, 40 - 70Hz adjustment range. See also UST range below. No Murphy equivalent.
- OVT series
- Discontinued Modex Automation AC Over Voltage Trip relays. Originally superseded by OVR range (also now discontinued, with no direct equivalent).
- PEM series
- Pilot Earth Monitoring relay (for checking the low resistance integrity of earth conductors), originally manufactured by Brian Bennett Electrical Engineering Ltd. (BBEE) and Modex Automation. Production discontinued in July 2004.
- RCR/S and RCR/L
- Discontinued elastic retaining straps for the Modex Automation range of plug-in timers and relays.
- SIM007
- Discontinued Modex Automation temperature simulators with an open board construction. The nearest equivalent is the (DIN cut-out mounted) SM200 below.
- SM200, SMT200, SMT200-TR
- Ex-Modex Automation temperature simulators, designed for form-fill, film and bag sealing (packaging) equipment.
- SM7
- Discontinued Modex Automation temperature simulators, 8 pin plug in. Nearest equivalent is the (DIN cut-out mounted) SM200 above.
- TC100, TC101, TC100X, TC101X TC100Z, TC100RT
- Discontinued Modex Automation temperature controllers, for connection/mounting in an 11pin base.
- TC200D
- Discontinued Modex Automation temperature controllers.
- TC400
- Discontinued Modex Automation temperature controllers.
- TC500(D)(T) / TC1000(D)(T)
- Discontinued Modex Automation temperature controllers, designed for mounting in a 92 x 92mm (DIN standard) panel cut-out. The TC500 series had a rotary dial to set temperature; the TC1000 used three decade thumbwheel switches. The 'D' option provided a 'deviation' meter (to indicate deviation between set and actual temperatures). The 'T' option provided an alarm relay that tripped at at a pre-set number of degrees above or below the set temperature (as detailed on the label). There are no Murphy equivalent/replacement products.
- Thermocouples
- For information on the discontinued range of Modex Automation thermocouples (mostly J and K type for use in the process control industry), click here. Several thousand variations of Modex thermocouple were produced, each type identified by a 4 figure tag number - please contact our sales engineers should you need details for each variant.
- TR100, TR200, TR300, TR301, TR1400
- Ex-Modex Automation delay on energisation time relays with 8 and 11 pin plug-in cases. The range included models TR100, TR100Z, TR101, TR200, TR300, TR300Z, TR301, TR301Z, TR302, TR1400, TR1401. The range was discontinued when the plug-in casing was made obsolete.
- TR25
- Ex-Modex Automation, 8 pin plug-in, delay on energisation timer. TR25P ('preset') variants had a recessed (screwdriver adjustable) time setting potentiometer. AC supply variants were discontinued in Jan. 2000, DC variants in Jan. 2003.
- TR40
- Ex-Modex Automation, 8 pin plug-in, interval timer. AC supply variants were discontinued in Jan. 2000, DC variants in Jan. 2003.
- TR900
- Ex-Modex Automation three attempt start timer, 8 pin plug-in. Many variants were produced. Discontinued as for TR100. No direct equivalent.
- TR1100
- Ex-Modex Automation true delay on de-energisation timer, 8 pin plug in. Discontinued as for TR100 above. No Murphy equivalent.
- TR1500
- Ex-Modex Automation asymmetric recycling timer, 8 pin plug in. Discontinued as for TR100 above. No Murphy equivalent.
- TRC200 / TRC200-T
- Discontinued Modex Automation temperature controllers.
- TRC500 / TRC500-T
- Discontinued Modex Automation temperature controllers, 92 x 92mm DIN cut-out mounted with LED display indication of set/actual temperature. No Murphy equivalent.
- TT12Z-TP / TT24-TP
- Discontinued Modex Automation temperature controllers, with a 'two-tier' open PCB construction.
- UST100 / UST101
- Discontinued Modex Automation under speed/frequency trip relays with 11 pin plug in case, 12 or 24V DC auxiliary supply, 110/240VAC input, 40 - 70Hz adjustment range. See also OST range above. No Murphy equivalent.
- UVT series
- Discontinued Modex Automation Under Voltage Trip relays. Originally superseded by UVR series (also now discontinued, with no direct equivalent).
- VR300
- Discontinued Modex Automation single phase AC under-voltage trip relay, 8 pin (octal) plug-in case. The devices were factory set (internally) to trip at a customer specified voltage. The closest equivalent is the DIN rail mounted, user-adjustable UVR series.