The PowerLine (PLD) module is ideally suited for today's hydraulic OEM, distributor or system builder. With both mechanical and electrical robustness paramount in the design priority, Windows™ compatible easy to use set-up software and full CE compliance means this one product can through the many configurations and features available, be used across multiple platforms, markets and applications.
PLD PRODUCT FEATURES:
- Pre-written Graphical User Interfaces for all modules
- Uni or bi-directional open loop pump stroker or valve controller
- Anti-stall option with auto - reverse feature
- +5V ref @ 5mA for local command joysticks, potentiometers etc
- Accepts all common analog command signals
- Sealed and protected to >IP68 ( NEMA 6P )
- Unique 'Solid' potting with flame retardant materials
The PowerLine has five (5) basic Configurable modes of operation available within the one module:
- Manual - Control of the output current through the graphical user interface
- Horse Power Limiter & Anti-Stall – Automotive style prime mover protection
- Horse Power Limiter & Anti-Stall with Reverse – Ideal for system such as auto-feed wood chippers or any applications that need a reverse feature if the engine starts to stall because of a forced load
- Horse Power Limiter & Anti-Stall with Max Command - Used to protect an engine from stalling, effectively de-coupling the load from the motor
- Valve Driver – Direct open loop control of single or dual coil valves or pump controls
Item | PLD Series | Description |
---|---|---|
Function | Multi Function Digital Valve Driver | General purpose Single or Dual coil open loop PWM valve driver |
Number of Coils | 1 Single or Dual | 0 to 3.0 Amps - See Cut Sheet |
Control Input | Voltage or Current | 0-5V, 0-10V, 4-20mA & 12±8mA |
Connector | Terminal Strip | Optional Weatherpack on 6" leads |
"Q" Option Mating Connector Kit | Mate for P1: 999-10159 Mate for J1: 999-10160 |
6 way tower and 6 way shroud on 6 inch cables will be provided |
Graphical User Interface (GUI) | P/N: 023-00206 | Set-up & Diagnostic software |
Feedback Input | Pulse only - software selectable | 0 to ±1V, 0 to 1.25V, 0 to 2.5V, 0 to 5V & 0 to 10V |
Ref Output | Yes and comes with 10K Pot & Knob | +5V @ 5mA ( current limited 1KΩ ) |
Physical | 94L x 94W x 10H mm | 3 x # 8 Mounting screws |
Mobile Equipment | IP68 (Module only) - derated for connector as required | Solid potted |
Temperature ºC | -40 to +85 Deg. C | Operating |
Voltage | 10 to 32 VDC | Reverse polarity protection and transient protection |