The Sentry range provides reliable float charging for vented lead acid or NiCd cells. Sentry chargers are based around an economical open-frame design, but can be supplied with a wall mounted enclosure complete with ammeter. The range is available in standard Sentry, Sentry 7 or UL1236/CSA approved versions. The Sentry range provides automatic, current limited and thyristor controlled charging of vented lead acid or NiCd batteries.
The units may be used in a wide range of industrial charging applications, including standby engines, pumps and generators. The charger uses an open frame construction, designed for surface mounting in an enclosed panel. Each unit consists of a transformer, rectifier and control circuit. The control circuit ensures that the charger maintains a battery voltage at the precalibrated float level, whilst supplying any additional loads current up to the specified maximum.
Sentry is designed to give a constant current output while battery voltage is below a ‘knee point’ (approx. 13V on a 12V LA). Above the knee-point, as the battery approaches its float voltage, the charger output current ramps down. This multi-stage charge regime gives an optimum combination of fast charge rate, followed by float charge without overcharging.
Auto Boost
Sentry UL series and Sentry 7 series units include an Auto boost feature. Auto boost provides a temporary increase in output voltage, equalizing the charge between cells and maximizing battery life and capacity. On Sentry UL series units, auto boost is triggered automatically when the battery falls below a preset voltage. On Sentry 7 series ‘A’ option chargers, Auto Boost can also be initiated manually by linking two ‘boost’ terminals, e.g. via a panel switch or momentary push-button. Once the batteries have reached the boost voltage level, the charger reverts to its normal float charge mode, preventing battery over-charge and gassing. Temperature compensation The optimum charge voltage for lead acid and NiCd batteries varies with ambient temperature. All Sentry UL series models are fitted with on-board temperature sensing and output compensation (3mV/cell decrease for each °C increase).
Temperature compensation
The optimum charge voltage for lead acid and NiCd batteries varies with ambient temperature. All Sentry UL series and Sentry 7 series models are fitted with on-board temperature sensing and output compensation (3mV/cell decrease for each °C increase).
Alarm output
Sentry 7 series ‘A’ option models include a relay output for remote alarm or signalling of charge fail conditions (no or low output current), e.g. due to AC supply or fuse failure, charger fault or high battery voltage.
Electronic self-resetting fuse
An electronic poly-fuse provides protection against DC output reverse polarity and short circuit faults. The fuse automatically resets on battery disconnection, allowing correct reconnection without manual replacement of fuses.
Installation and connection
Electrical connection of the AC supply input and DC output is via spring clamp terminals. Transformer, circuit board and terminal blocks are mounted on an open chassis baseplate/heatsink, designed for surface mounting in an enclosed control panel.
Specifications
Sentry series
- Power supply
- 110/120V units: 104 – 127 VAC
- 220/240V unites: 207 - 254 VAC
- Operating voltage:
- Operating frequency: 50/60 Hz.
- DC Charge Output
- S100: 100W
- S120: 120W
- S100: 12V/24V
- S120: 24V
- S100: 5A/3A
- S120: 5A
- Maximum power output
- Nominal voltage
- Maximum current limit:
- Float / boost voltages: see ‘output calibration’ section
- Physical
- S100 models: 1.8 kg / 4.0 lb
- S120 models: 2.6 kg / 5.8 lb
- Operating temperature: –10 to +55°C / +14 to +131°F
- Dimensions: see diagram
- Weights:
- Electromagnetic compatibility: EN 50081-2 / EN 50082-2
Sentry 7 series
- Power supply
- Operating voltage: 120V units: 104 – 127 VAC
- Operating frequency: 50/60 Hz.
- DC Charge Output
- S700: 100W
- S7120: 120W
- S700: 12V
- S7120: 24V
- SPDT (volt free/dry) relay contacts, de-energised on fault, rated 1A max @ 30 VDC (resistive load)
- Maximum power output
- Nominal voltage
- Maximum current limit: 5A
- Float / boost voltages: see ‘output calibration’ section
- Charge fail alarm output (‘A’ option models)
- Physical
- S7100 models: 1.8 kg / 4.0 lb
- S7120 models: 2.6 kg / 5.8 lb
- Operating temperature: –10 to +55°C / +14 to +131°F
- Dimensions: see diagram
- Weights:
- Electromagnetic compatibility: EN 50081-2 / EN 50082-2
Sentry UL series
- Power supply
- Operating voltage: 120V units: 104 – 127 VAC
- Operating frequency: 50/60 Hz.
- DC Charge Output
- SUL100/ESUL100: 100W
- SUL120/ESUL120: 120W
- SUL100/ESUL100: 12V/24V
- SUL120/ESUL120: 12V/24V
- SUL100/ESUL100: 5A/3A
- SUL120/ESUL120: 10A/5A
- Maximum power output
- Nominal voltage
- Maximum current limit:
- Float / boost voltages: see ‘output calibration’ section
- Physical
- SUL100 models: 1.8 kg / 4.0 lb
- SUL120 models: 2.6 kg / 5.8 lb
- ESUL100 models: 1.8 kg / 4.0 lb
- ESUL120 models: 2.6 kg / 5.8 lb
- SUL100/120
- BBGQ2: UL1236, CSA22.2 no. 107.2
- ESUL100/ESUL120
- BBGQ: UL1236, CSA22.2 no. 107.2
- Operating temperature: –10 to +55°C / +14 to +131°F
- Dimensions: see diagram
- Weights:
- Electromagnetic compatibility: EN 50081-2 / EN 50082-2
- UL approvals
For more information about this product, you can download the related literature here:
- Sentry (open-frame) Sales Bulletin (cd0023)
- Sentry 7 (open frame) Sales Bulletin (cd0024)
- Sentry UL (open-frame) Sales Bulletin (cd0025)
- Sentry UL (enclosed) Sales Bulletin (cd0026)
- Sentry UL Installation, Operation and Maintenance Manual (ci0030)
- Sentry UL (open-frame) certificate of compliance
- Sentry UL (enclosed) certificate of compliance
Discontinued/Archived Literature:
- Sales Bulletin (es; rev 07/2003)
Comments
0 comments
Please sign in to leave a comment.